Criteria | Supporting Features | Remarks (e.g., definition, equivalent facilitation, scope of support provided) |
1194.21(a) When software is designed to run on a system that has a keyboard, product functions shall be executable from a keyboard where the function itself or the result of performing a function can be discerned textually. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - ability to perform functions from the keyboard only
- logical movement of focus through the controls
- proper operation of unique keystrokes and access keys, including those listed in the product documentation
Exceptions: - Need to press Tab Key twice to Navigate from Help to OK button in Member Selection. Bug ID: 14048358
- Navigation around the options in Query Designer panel is restricted. Bug ID: 17228097
- Navigation around the options in Smart Slice Designer panel is restricted. Bug ID: 17228578
- POV (point of view) values aren't keyboard accessible and not read out in the Cell Comment/Doc Attachment dialog box; however, the same functionality can be accessed from the Hyperion Planning web application.
- Autoscroll missing with tabbing in the Task Details pane
- The process management promotional path UI doesn't support this standard; however, the same functionality can be accessed from the Hyperion Planning web application.
|
1194.21(b) Applications shall not disrupt or disable activated features of other products that are identified as accessibility features, where those features are developed and documented according to industry standards. Applications also shall not disrupt or disable activated features of any operating system that are identified as accessibility features where the application programming interface for those accessibility features has been documented by the manufacturer of the operating system and is available to the product developer. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Sticky Keys, Slow Keys, Filter Keys, Bounce Keys, and Toggle Keys.
- High Contrast and Large Print themes.
|
1194.21(c) A well-defined on-screen indication of the current focus shall be provided that moves among interactive interface elements as the input focus changes. The focus shall be programmatically exposed so that assistive technology can track focus and focus changes. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Visual indication of the position of the cursor within text, and visual indication of the focused component, including with the High Contrast and Large Print theme.
Exception: - Rows collapse/expand button and the "Base sets of ..." items on the SmartView Query panel are focused twice. Bug ID: 13614654
- Reverse tab order does not working in the options dialog. Bug ID: 17072525
- Focus and reverse tab order not working correctly in cell comments window. Bug ID: 17072991
- When connecting to OBI EE, in view designer window tab order/focus is not working for some cases. Bug ID: 17241061
|
1194.21(d) Sufficient information about a user interface element including the identity, operation and state of the element shall be available to assistive technology. When an image represents a program element, the information conveyed by the image must also be available in text. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Meaningful icon/image/object identification including object state change on selection (e.g., folder open on selection)
Exceptions: - Screen reader is not reading the filter operator in the "Prompt Selector" dialog. Bug ID: 14823403
- Screen reader reading wrong text in Smart View pane when Analysis is selected. This is applicable only for an OBI EE source where a pivot table is inserted. Bug ID: 14809646
- Screen reader announces all row/column values preceeding the current cell value; row/column headers aren't explicitly announced for a focussed cell value within the excel grid area. However, the same functionality can be accessed from the Hyperion Planning web application.
- Grid cell info (Cell text, doc attachment, supporting detail, drill through) not detected by screen reader. Users have to rely on cell styling to identify cell info. (Bug ID 9083398). However, the same functionality can be accessed from Hyperion Planning web application.
- POV (point of view) values aren't keyboard accessible and not read out in the Cell Comment/Doc Attachment dialog box; however, the same functionality can be accessed from the Hyperion Planning web application.
|
1194.21(e) When bitmap images are used to identify controls, status indicators, or other programmatic elements, the meaning assigned to those images shall be consistent throughout an application's performance. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Meaningful icon/image/object identification including object state change on selection (e.g., folder open on selection)
Exceptions - Screen reader does not announce lines under insert new reporting object control. Bug ID: 17227054
- Screen reader announces incorrect steps when tabbing to OK button in member selection dialog. Bug ID: 17228334
- Screen reader does not mention name of data sources on the shared connections panel. Bug ID: 17226962
|
1194.21(f) Textual information shall be provided through operating system functions for displaying text. The minimum information that shall be made available is text content, text input caret location, and text attributes. | Product has been developed to conform to this standard subject to the remarks on the right. | Textual information is provided through operating system functions for displaying text. |
1194.21(g) Applications shall not override user selected contrast and color selections and other individual display attributes. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Windows or other OS-level color settings are not over-ruled by product
Exceptions: - In High Contrast mode:
- Home Panel high contrast focus is not visible with keyboard and inconsistent on mouse over
- Inconsistent focus on: Home icon and dropdown, Options dialog box left hand tab structure
|
1194.21(h) When animation is displayed, the information shall be displayable in at least one non-animated presentation mode at the option of the user. | Not Applicable | The product contains no animation. |
1194.21(i) Color coding shall not be used as the only means of conveying information, indicating an action, prompting a response, or distinguishing a visual element. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Alternative means are used for conveying color related information
|
1194.21(j) When a product permits a user to adjust color and contrast settings, a variety of color selections capable of producing a range of contrast levels shall be provided. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Windows or other OS-level color settings are not over-ruled by product
|
1194.21(k) Software shall not use flashing or blinking text, objects, or other elements having a flash or blink frequency greater than 2 Hz and lower than 55 Hz. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - elements that flash or blink between 2 Hz and 55 Hz
|
1194.21(l) When electronic forms are used, the form shall allow people using assistive technology to access the information, field elements, and functionality required for completion and submission of the form, including all directions and cues. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - User interface component labels are associated with the fields they are labeling.
- Edit text fields have a label associated with them.
- Label associations and form controls are exposed to assisstive technologies
- Reading of screen text
- Screen elements under magnification retain readability and are recognizable
- AT product successfully tracks cursor focus
Exceptions: - Rows collapse/expand button and the "Base sets of ..." items on the SmartView Query panel are focused twice. Bug ID: 13614654
|